8 INSPECTION AND MAINTENANCE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
143
Pub. No. K29001-00320 Revision: 1
3 After bleeding air, turn the cap (1)
clockwise while pushing it.
• Make the cap (1) to contact with the head
packing (2).
Fig. 8-17 Priming Pump - Operation <A-type>
4 Retightened by 80 to 100°.
• Tool: Adjustable wrench
Fig. 8-18 Priming Pump - Operation <A-type>
5 Check the head packing (3) for an
abnormality such as deformation or
scratches.
Fig. 8-19 Priming Pump - Operation <A-type>
• If the head packing has an
abnormality such as deformation or
scratches, the priming pump must be
replaced. Contact your SME dealer
"CONTACT LIST" (→ Page 8).
<B-type>
1 Move the handle up and down.
ï‚®Fuel is discharged.
Fig. 8-20 Priming Pump - Operation <B-type>
• There is not a locking mechanism.
â– Water Separator - Bleed Air
Bleed air from the water separator.
• The water separator is outside the
scope of our supply.
For the details, refer to such a
document as the corresponding manual
of the generator and the supplier's
operation manual.
(1)
(2)
80 to 100°
(3)