8 INSPECTION AND MAINTENANCE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
176
Pub. No. K29001-00320 Revision: 1
4 Dry the pre-cleaner naturally and
sufficiently.
Fig. 8-113 Pre-cleaner - Clean 3
5 Check the pre-cleaner for tears.
ï‚®If a tear or other damage is found, replace
the pre-cleaner with a new one.
6 Install the pre-cleaner (2) on the
silencer.
• Check that the hook-and-loop fastener (1) is
retained firmly so that the pre-cleaner will not
drop off.
Fig. 8-114 Pre-cleaner - Install
Air Cleaner - Check and Service
Check the air cleaner for clogging and clean the air
cleaner element.
• The air cleaner may be outside the
scope of our supply. For the details,
refer to such a document as the
specification sheet prepared by the
generator manufacturer.
• If it is not supplied by SME, follow the
instructions in the supplier's operation
manual.
â–  Air Cleaner - Check for Clogging
Check the air cleaner for clogging.
â–  Air Cleaner Element - Clean
Clean the air cleaner element.
• If necessary, replace the air cleaner element with
a new one.
(2)
(1)
Make sure that the air cleaner is free
from clogging.
* Insufficient intake air could result in loss of
power, incomplete combustion, exhaust gas
temperature rise, and overspeed of the
turbocharger.