TABLE OF FUNCTIONS CONNECTED WIRED REMOTE CONTROLLERS (RC-E4, E5)
NO. Functions SRK SRR SRF
Outline of function Remarks
1
Several remote controllers for 1unit
Indoor unit can be connected max. 2 remote controllers.
2 Control of several indoor units
One remote controller can be connected toa max. of 16
indoor unit.
3
Plural Control × ×
One outdoor unit can be connected to a max. of 4indoor
units.
Only SRK50,60ZJX-S,S1
4
Central control
Signal of center mode from Center conslole can be
restricted to operation of remote controller.
5 Run/Stop
6
Change operation mode
Display of operation mode range is automatically decided
from the indoor unit's imformation.
7
Adjust fan speed
Display of airflow range is automatically decided from the
indoor unit's imformation.
8
Auto swing of flap ×
Display of airflow direction ON/OFF is automatically
decided from the indoor unit's imformation.
Flap control only. Louver cannot be controlled.
9
Setting of air flow direction × × ×
Setting of air flow direction for indoor unit that can be
changed airflow direction.
10 Setting of temperture
Temperture range can be set from 18 degree to
30 degree. Carving 0.5 is rounded up.
11 Timer operation
Sleep timer mode, Off timer mode, On timer mode,
Weekly timer mode.
Worm up timer and sleep control of on timer
mode is impossible.
12 Grill auto mode × × × Grill auto mode. RAC unit does not have this function.
13 Setting of grill auto mode × × × Simple setting of grill auto mode. RAC unit does not have this function.
14 Ventilation control × × ×
Air infiltration can be controlled by the indoor unit that
has this function.
RAC unit does not have this function.
15 Display of unit number Display address number of remote control. Address setted by SC-BIK-N for RAC
16
Service switch-1: Display of error
data
Display and memorize the error code data that is checked
finally.
Only error code is used in the RAC unit.
17
Service switch -2 display of
operation data
Display operation data. RAC unit can be displayed some data.
18 Trial run Cooling operation signal is sent to the indoor unit.
19 Forced operation of drain pump × × Forced operation of drain pump is sent to the indoor unit. Option parts for SRR
20 Setting of compressor frequency Fixing compressor frequency.
21 Quiet mode × × × On timer in order to start quiet mode. RAC unit does not have this function.
22
Auto address change from remote
control
× × × Auto address can be changed from remote control. RAC unit does not have this function.
23 Indoor unit's address set of master × × × Adapt controller for 3 pipe system. RAC unit does not have this function.
24 Filter reset × × ×
Turning off signal display of filter sign and sending reset
signal of operating time.
RAC unit does not have this function.
25
Clear memory of error code in
remote control
Reset memory that remote controller has the error code.
26
Clear memory of error code in the
indoor unit
Reset memory of error for the indoor unit.
27 Clear address in indoor unit × × × Reset memory of address for the indoor unit. RAC unit does not have this function.
28 Reset CPU Reset outdoor or indoor CPU.
29 Function setting
It is possible to set the function of remote control and
indoor unit.
RAC unit can be set a part of function.
30 Setting of temperature range Set Max and Min temperature.
For RAC models, only the range from 18 to
30 is available.
31 External input
External input from CNT terminal can be switched
between all unit operation and individual operation.
32 Auto adjustment of static pressure × × × Change auto adjustment of static pressure. RAC unit does not have this function.
33 Setting of static pressure × × ×
Displayed part blinks on and off when it recives a
signal about auto adjustment of static pressure mode.
RAC unit does not have this function.
34 Filter sign × × ×
Displays filter sign via signal from indoor unit when
counting time achieves target time.
RAC unit does not have this function.
○:OK, △:Conditionally OK, ×:N/A
If wired remote controller (optional part) is connected to the following indoor units, some of the functions cannot be used. Please
see following table for details.
Wall mounted typeSRK
**
ZJX-S1,ZJX-S,ZJR-S,ZJ-S,ZK-S
Floor standing typeSRF
**
ZJX-S
Ceiling concealed typeSRR
**
ZJ-S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM80ZJ-S1 and is the answer not in the manual?

Mitsubishi SCM80ZJ-S1 Specifications

General IconGeneral
BrandMitsubishi
ModelSCM80ZJ-S1
CategoryAir Conditioner
LanguageEnglish

Related product manuals