'18 • SRK-SM-259
-
38
-
DescriptionItem
ConnectorCN20S
CNEEV
CNFAN
CNTH
Model
Power cable, indoor-outdoor connecting wires
The wire numbers include Earth wire
(Yellow/Green).
25,35 2.5mm x 3 28 1.5mm x 49
2
2
2
N
SWITCHING POWER
CIRCUIT
F1
250V 2A
NW
F3 T 1A L 250V
NU
NV
P
250V 20A
F2
V
V
TRANSISTOR
POWER
(WHITE)
U
(RED)
W
(BLACK)
U
W
M
3~
COMPRESSOR
MOTOR
M
FAN MOTOR
++
F4
250V 10A
CIRCUIT
PAM
PCB ASSY
T1 T2
FILTER
NOISE
R.IN
S.IN
C-2
G1
(BLACK)
(WHITE)
(RED)
GREEN)
(YELLOW/
T 250V E 15A
F7
1
2
3
L
N
M
CN20S CNTH CNEEV
CNFAN
HEAT EXCH. SENSOR
(OUTDOOR UNIT)
OUTDOOR AIR
TEMP.SENSOR
DISCHARGE PIPE
TEMP. SENSOR
SOLENOID COIL FOR
4-WAY VALVE
ELECTRIC EXPANSION
VALVE(COIL)
REACTOR
(YELLOW)
(ORANGE)
BLOCK
TERMINAL
TB1
POWER CABLE
SIGNAL WIRE
EARTH WIRE
1
3
G2
GREEN)
(YELLOW/
GREEN)
(YELLOW/
Switchgear or circuit breaker capacity should be chosen according to national or regional electricity
The power cable specifications are based on the assumption that a metal or plastic conduit is used
with no more than three cables contained in a conduit and a voltage drop is 2
%. For an installation
falling outside of these conditions, please follow the national or regional electricity regulations.
regulations.
t°
t°
t°
t°
4
2 2 2 2
3
MAX running current Power cable
wire size x number
*
(A)
Power cable length
(m)
Connecting cable
wire size x number*
Power source
1 Phase
220-240V 50Hz
Meaning of marks
*
(2) Outdoor units
Models SRK25ZSP-W, 35ZSP-W
RWC000Z324