Installation Section 2
2-14
Part Number 020002777 10/11
Plumbing – General
CONNECTING THE SYRUP AND WATER LINES
Model 138CDA or 138CDAX
1. Locate the Barb-stem splicers and tab-clamps in the
installation kit.
NOTE: The Installation Kit provides syrup connections
for 1/2 or 3/8 ID conduits. The circulating carbonated
Water Lines are supplied with 1/2 Barbs only. Determine
the conduit size prior to the attaching Barb systems.
2. Attach the 1/4" Barb of the 1/4" x 1/2" or 1/4" x 3/8"
Barb splicer to the Syrup Lines in the tower labeled
#1, #2, #4, #5, #6, #7, and #8. clamp in place with
tab clamp.
3. Attach the four (4) 1/2" x 1/2" Barb splicers to the
tower lines labeled "AF or AR" and "BF or BR".
Clamp in place with tab clamp (refer to "Note"
below).
4. Route the beverage conduit up to the tower. If the
lines of the conduit are different lengths, always
connect the shortest line first. Use two (2) tab
clamps per connection.
5. Using the plumbing diagram (located in this manual)
as a guide for steps 5 through 7 attach the tower
Syrup Lines labeled #1, #2, #3, #4, #5, #6, #7 and
#8 to the corresponding numbered or colored line of
the conduit. Clamp in place.
6. Connect the plain water supply to the line labeled
"WF or WR". clamp with tab clamp.
7. Attach the Carbonated Water Line to the line labeled
"AF or AR" and "BF or BR". Clamp in place.
NOTE: If a Single Circuit is used, run "AF or AR" In and
"AF or AR" Out to "BF or BR" In. Route "BF or BR" back
to conduit.
Model 136EDA, 136EDAX, 138EDA, or 138EDAX
1. Locate the Barb stem splicers and tab clamps in the
installation kit.
NOTE: The Installation Kit provides syrup connections for
1/2 or 3/8 ID conduits. The circulating carbonated Water
lines are supplied with 1/2 Barbs only. Determine the conduit
size prior to the attaching Barb systems.
2. Attach the 1/4" Barb of the 1/4" x 1/2" or 1/4" x 3/8" Barb
splicer to the Syrup Lines in the tower labeled #1, #2,
#3, #4, #5, and #6. Clamp in place with tab clamp.
3. Attach the two (2) 1/2" x 1/2" Barb splicers to the tower
lines labeled "AF or AR". Clamp in place with tab clamp.
4. Route the beverage conduit up to the tower. If the lines
of the conduit are different lengths, always connect the
shortest line first. Use (2) tab clamps per connection.
5. Using the Plumbing diagram (in this manual) as a guide
for steps 5 through 7, attach the tower Syrup Lines
labeled #1, #2, #3, #4, #5, and #6 to the corresponding
numbered or colored line of the conduit. Clamp in place.
6. Connect the plain water supply to the line labeled "WF
or WR". Clamp with tab clamp.
7. Attach the Carbonated Water Line to the line labeled
"AF or AR". Clamp in place