Operation Section 3
3-4
Part Number 020002777 10/11
TOP-OFF PROGRAM MODE
Top-Off Program Mode
To enter the top-off program mode, simultaneously
press CAL button and the Size 4 button () on any station.
You may also press the CAL button five times within
three seconds. The CAL light will flash five (5) times and
then remain “on”.
Enabling / Disabling the individual station Top-off
Enabling the individual station top-off allows every size
dispensed on this station to pour all the volume
programmed in two (2) pours with a 3 second delay
between pours. Disabling the individual station top-off
allows every size dispensed on this station to pour all the
volume programmed in one pour.
1. Press the STOP-FILL button on the station desired
to change the top-off mode.
2. The CAL light will immediately flash five (5) times to
indicate the top-off mode has been toggled. If the
respective station was disabled for top-off, then it will
toggle to enable for top-off. If the respective station
was enabled for top-off, then it will toggle to disable
for top-off.
Exiting the Top-off Program Mode
To exit the Top-off Program Mode, press the CAL button
one (1) time turning “off” the CAL light. All station top-off
mode changes made during this session will be
permanently stored.
TEST AND SANITATION MODE
1. With the power “off”, press the CAL button and turn
power “on” simultaneously.
2. Release the CAL button. The portion control board
will sequence each station for 4 seconds starting
with the left most (station No. 1).
3. Check that each LED on the Portion Control board
comes “on” sequentially and all valve solenoids
come “on”.
NOTE: If the drain can support more than one (1) valve
pouring at a time, press the STOP-FILL button on the
station number for the number of valves flowing
simultaneously.
Example: At station number 3, press the STOP-FILL
button. Three (3) valves will flow simultaneously.
NOTE: If the LED light does not come “on” for any
station(s), the Portion Control board is bad. If the LED
light comes “on” but the valve does not come “on”, check
wiring and valve solenoids.
INSTRUCTIONS FOR DUAL FLAVOR STATIONS
NOTE: Station No. 2 and 4 have Dual Flavors
1. Press the flavor and it's associated LED will come
"on"
2. Press any size button to dispense this flavor and
size. If the required flavor button LED is already
"on", press the size button desired.
NOTE: The left LED flavor is the default on both stations.
ENTERING WATER/SODA PROGRAMMING MODE
To enter water/soda programming mode, press and hold
the CAL button SIZE 3 buttons. The CAL light will come
ON instantly.
Pressing SIZE 1 button on any station, will set the
special WATER solenoid driver J10 to come ON with all
dispenses of THIS station, as well as water button
dispensing from this station. An automatic 2 second pour
of water from this station will occur, to verify setting.
Pressing SIZE 4 button on any specific station, will set
the special SODA solenoid driver J9 to come on. An
automatic 2 second pour of water from this station will
occur to verify setting.
You must also make sure the correct WATER and SODA
solenoids (from the stations you just programmed) are
wired correctly to J9 and J10 respectively.
Equipment Setup and Close Procedure
EQUIPMENT SETUP PROCEDURE
1. Ensure that all valve nozzles are attached to the valves.
2. Observe pressure of CO
2
high pressure tank of 500 psi
(34 bar) or more, or bulk CO
2
tank of 150 psi or more.
Primary regulator set at 90 psi (6 bar) and the secondary
regulator set at 35 psi (2.4 bar).
3. Observe the control panel to verify that all pressure
gauges are set at correct operating pressures.
4. Check the syrup tanks to make sure a sufficient number
of tanks are connected in series to satisfy business
volume.
5. Clean syrup inlet and outlet quick disconnects at the
same time tanks are replaced. Rinse disconnects in clean
potable water.
EQUIPMENT CLOSE PROCEDURE
1. Clean the underside of the dispensing tower around the
nozzle area with a clean damp towel.
2. Pour at least 60 oz (1.8 liters) of warm water down the
drain openings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Multiplex 138LDAX and is the answer not in the manual?

Multiplex 138LDAX Specifications

General IconGeneral
BrandMultiplex
Model138LDAX
CategoryDispenser
LanguageEnglish

Related product manuals