Section 3 Operation
Part Number 020002777 10/11 3-3
Program modes
PROGRAM MODE CAL NO. 1 (TOTAL VOLUME)
To enter the Calibrate No. 1 mode, simultaneously press
the CAL button and the Size 1 button (1) on any station.
You may also press the CAL button three times within
three seconds. The CAL light will come “on” constantly.
Volume Sizing
NOTE: Use a Calibration Cup (or an appropriate size
cup with the proper amount of ice).
1. Press the respective size button for that cup (0, 1, 2,
3, or 4) at that station.
2. Fill the cup with product to the correct level.
NOTE: This same size button may be started and
stopped as many times as desired to acquire the correct
level while letting the drink settle. All times for the same
station and size are additive in the program session.
3. Repeat volume sizing procedure for all sizes and
stations needing programming.
Flow Rate Calibration
In the Calibrate No. 1 Mode, press any STOP-FILL
button one (1) time. That respective valve will flow for
exactly 4 seconds allowing for checking or adjusting the
valve flow rate.
One Station Sets All
Immediately after entering the Calibrate No. 1 Mode,
press any STOP-FILL button two (2) times in less than
1 second. The CAL light will flash constantly, 2 times per
second. Now all volumes on that station programmed in
this session, will copy to all other stations when exiting.
Exiting the Program Mode, CAL No. 1
To exit, press the CAL button one (1) time turning “off”
the CAL light. All volume changes made during this
session will be permanently stored.
PROGRAM MODE CAL NO. 2 (INCREMENTAL)
To enter Calibrate No. 2 Mode, simultaneously press the
CAL button and the Size 2 button (2) on any station. The
CAL light will flash constantly, one (1) time per second.
Volume incrementing/decrementing
1. Press the size button (0, 1, 2, 3, or 4) on the specific
station that needs a small increment of time
adjustment. The CAL light will come “on” constantly
indicating this size/station time is selected.
2. To increase time, press the Size 4 button () at this
time. Each press of the Size 4 button () will increase
total selected size stored time by 0.1 seconds. The
CAL light will go “off” every time button is pressed.
Example: 10 presses = 1 second.
3. To decrease time, press the Size 1 button () at this
time. Each press of the Size 1 button () will decrease
total selected size stored time by 0.1 seconds. The
CAL light will go “off” every time button is pressed.
4. Press STOP-FILL button on this station to
temporarily save new time for this size this station.
The CAL light will resume flashing.
5. Repeat procedure 1 through 5 for any other size or
station needing incremental time programming
Exiting the Program Mode, CAL No. 2
To exit, press the CAL button one (1) time turning “off”
the flashing CAL light. All incremental volume changes
made during this session will be permanently stored.
PROGRAM MODE CAL NO. 3 (WATER/SODA)
NOTE: This is set at the factory to station number 2
(water) and 4 (soda). This may have to be reset in the
field if someone inadvertently changes location, or if the
location must change stations.
To enter water/soda programming mode, simultaneously
press the CAL button and SIZE 3 button () on any station
(refer to figure above). The CAL light will come “on”
constantly.
1. Before changing the water/soda pour stations, you
must make sure the correct WATER and SODA
solenoids (from the stations to be programmed) are
wired correctly to J9 and J10 respectively.
2. Pressing SIZE 1 button on any station, will set the
special WATER solenoid driver J10 to come ON with
all dispenses of THIS station, as well as the WATER
button dispensing water from this station.
An automatic 2 second pour of water solenoid from this
station will occur, to verify setting.
3. Pressing SIZE 4 button on any specific station, will
set the special SODA solenoid driver J9 to come ON
with all dispenses of this station, as well as the
SODA button dispensing soda water from this
station.
An automatic 2 second pour of water solenoid from this
station will occur, to verify setting.
Exiting the programming mode, CAL No. 3.
To exit, press the CAL button one (1) time turning “off”
the CAL light. All water/soda changes made during this
session will be permanently stored.