ports from your PXIe-8862 BIOS allows those 100 bus segments to be allocated to
remote chassis.
For more information, go to ni.com/support.
My chassis or controller does not appear in MAX. How do I use MAX
to identify and configure my PXI system?
If you are using MAX to configure your PXI system, you must install the PXI Platform
Services soware on your controller to identify NI PXI and PXI Express chassis and
modules in MAX. You can install PXI Platform Services from the soware CD included
with your controller or from ni.com/downloads.
PXI Platform Services version 21.5 or later supports the PXIe-8861.
My CMOS is corrupted. How do I set it back to default?
There are two methods that you can use to reset the CMOS.
First Method
1. Enter the BIOS setup program.
2. Press <F9> to load BIOS defaults.
3. Answer Y (Yes) to the verification prompt.
4. Select Save and Exit Setup.
Second Method
1.
Power o the chassis.
2. Remove the controller from the chassis.
3. Press the Clear CMOS button (SW1) for 2 to 3 seconds as shown in the
following figure.
4.
Reinstall the controller in the chassis.
© National Instruments
17
PXIe-8861 Getting Started Guide

Other manuals for National Instruments PXIe-8861

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments PXIe-8861 and is the answer not in the manual?

National Instruments PXIe-8861 Specifications

General IconGeneral
BrandNational Instruments
ModelPXIe-8861
CategoryController
LanguageEnglish

Related product manuals