3-4 | ni.com
Chapter 3 External Control
18 OUT ON/OFF CONT Output on/off terminal.
On when set to LOW (0 to 0.5 V) or shorted (CF10: Lo);
Off when set to HIGH (4.5 or 5 V) or open (CF10: Lo)
On when set to HIGH (4.5 to 5 V) or open (CF10: Hi);
Off when set to LOW (0 or 0.5 V) or shorted (CF10: Hi).
19 A COM External signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing
input. When remote sensing is not being performed, this is connected
to the negative output.
20 REF OUT External resistance control terminal; 5.25 V (CF07: Lo) or 10.5 V
(CF07: Hi). The maximum output current 2.5 mA.
21 I PGM Terminal used to control the output current with an external voltage
or external resistance.
0 to 5 V; 0 to 100% of the rated output current (CF07: Lo).
0 to 10 V; 0 to 100% of the rated output current (CF07: Hi).
22 V PGM Terminal used to control the output voltage with an external voltage
or external resistance.
0 to 5 V; 0 to 100% of the rated output voltage (CF07: Lo).
0 to 10 V; 0 to 100% of the rated output voltage (CF07: Hi).
23 A COM External signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing
input. When remote sensing is not being performed, this is connected
to the negative output.
24 I MON Output current monitor.
0 to 100% of the rated output current is generated as a voltage
between 0 and 5 V (CF08: Lo) or a voltage between 0 and 10 V
(CF08: Hi).
25 V MON Output voltage monitor.
0 to 100% of the rated output voltage is generated as a voltage
between 0 and 5 V (CF08: Lo) or a voltage between 0 and 10 V
(CF08: Hi).
1
Open collector output: Maximum voltage of 30 V and maximum current of 8 mA.
Table 3-1. J1 Connector Signals (Continued)
Pin Signal Name Description

Table of Contents

Other manuals for National Instruments RMX-4125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments RMX-4125 and is the answer not in the manual?

National Instruments RMX-4125 Specifications

General IconGeneral
BrandNational Instruments
ModelRMX-4125
CategoryPower Supply
LanguageEnglish

Related product manuals