EasyManuals Logo

Navien NCB500-2S/37K User Manual

Navien NCB500-2S/37K
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
Replacement of Parts 101
6.2.12 DHW Heat exchanger
1. Turn off the gas supply to the unit.
2. Turn off the 230V power supply to the unit.
3. Turn off the water supply to the unit. Drain all water from
the appliance.
4. Remove the gas supply unit.
5. Remove the two screws at the DHW exchanger.
Figure 23
6. Replace with the new DHW Exchanger.