7 Start-up / Operation
Start-up of the vibrators can be
performed immediately after the
correct installation.
At temperatures ≤ 10°C higher starting
pressures (more than 2 bar) may be
required. A start-up control starts the
unit with approx. 5 bar and then
reduces the pressure to 2 bar.
The frequency can be adjusted or
regulated with the pressure regulator
on the service unit. Use a 3/2-way
valve!
The amplitude can be regulated with a
throttle installed in the exhaust air
outlet.
Attention: Reduced cross-sections
(observe NW) already throttle.
Standard installation
Special plans on request
NTS 100/01 - 2-3 drops/min
If lubricated compressed air or nitrogen
is mandatory for the NTS (housing
group 2, orange or stainless steel
housing and the NTS 21/04):
Fill the oil-mist lubricator with acid-free
and resin-free pneumatic oil, ISO
viscosity class according to DIN 51519,
VG 5 to VG 15.
Please consider the operating
temperature:
In case of temperatures higher than
150°C (special versions) please
contact Netter GmbH.
NTS 75/01 - 2-3 drops/min
NTS 50/01 - 2-3 drops/min
NTS 70/01 - 2-3 drops/min
NTS 54/01 - 3-4 drops/min
NTS 50/04 - 4-5 drops/min
NTS 21/04 - 5-6 drops/min
NTS 50/08 - 5-6 drops/min
NTS 50/10 - 5-6 drops/min
NTS 30/10 - 5-6 drops/min
NTS 50/15 - 5-6 drops/min
NTS 50/20 - 5-6 drops/min
NTS 30/20 - 5-6 drops/min
NTS 24/20 - 5-6 drops/min
NTS 50/40 - 9-12 drops/min
NTS 20/40 - 9-12 drops/min
ATTENTION:
Adjust number of drops while unit is running.
Only after the adjustment and correct function of the lubricator the
unit is ready for operation.