EN
English – 1
The planning and production of the devices making up the control
units for UST1K doors and the information contained in this user's
manual are perfectly compliant with the current safety standards.
Nevertheless, incorrect installation can cause serious injury to the
persons that work on the system or that use it. For this reason, dur-
ing installation it is important to follow all the instructions contained
in this manual.
Do not start installation if you have any doubts of any kind
and, if necessary, contact the Nice Assistance Service.
WORK IN SAFE CONDITIONS!
ATTENTION! – It is important to follow these instructions for
reasons of safety.
ATTENTION! – It is important to keep these instructions for
future consultation for reasons of safety.
Strictly follow these instructions:
– Make only the electrical connections described in this man-
ual: incorrect wir ing could cause serious damage to the
system.
– If used outdoors, the power supply cable must be com-
pletely protected with a special protection pipe.
In view of the risks associated with the installation and with
sy stem control, it is necessary to install the product in the
packaging, following these instructions:
–Executeonlythemodicationsdescribedintheuser'sinstructions
onthedevices. Anyothermodicationcancauseserious mal
Description and use
UST1K is a control unit for rolling shutters and sectional doors with
three-phase or single-phase motors. All the common safety ele-
mentscanbeconnected.
Withtheapplicationofvariousbusconnections(modules),otherap-
plicationsarepossible.
For openingand closing a door,just pressthe special button in-
stalledonthecoverortheexternalbutton.
It is possible to open and close the door wirelessly in automatic
mode.
Any other use is considered improper! The manufacturer de-
clines any responsibility whatsoever for damages caused by
improper use of the various system devices not compliant
with what is indicated in this manual.
The plant manufacturer is responsible for the complete plant. He
mustfullthecurrentregulationsanddirectives(e.g.DIN1986,EN
12050).Heisresponsiblefordrawingupthetechnicaldocumenta-
tionoftheentireplanttobesuppliedtogetherwiththeplant.
It is mandatory to comply with the provisions and national
and local regulations regarding installation, accident preven-
tion and safety at the workplace.
Disconnect the system from the electrical power supply dur-
ing works.
Checks before installation
Carefullyreadtheseassemblyanduseinstructionsbeforebeginning
installation of the control unit.
Themanufacturerdeclinesallresponsibilityandobligationofwarran-
tyifanyarbitrarychangesinconstructionaremadewithoutprevious
writtenauthorisationorinstallationnotcompliantwiththeassembly
instructions is executed.
The plant manufacturer must ensure that the EMC directives, low
voltage directives, machinery directives and directives on construc-
tionproductsareobserved.
ATTENTION!
Thiscontrolunitcannotbeusedinareasatriskofexplosion.
ATTENTION!
ConnectthepowersupplycabletoterminalX1(L1,L2,L3)andto
thePEterminalofthemainboard.
Thepowersupplycablemustbeputinsafeconditionswithfuses
3x6Aor3x10A.
The fuse must have a value such that the gearmotor makes the fuse
tripifitbecomesblocked.
GENERAL RULES OF SAFETY
ENGLISH
KNOWLEDGE OF THE SYSTEM AND
PREPARATION FOR INSTALLATION
GENERALRULESOFSAFETY 3
PREPARATIONFORINSTALLATION 3
CONTROLANDCONNECTIONELEMENTS 4
MECHANICALLIMITSWITCHSETTING 7
DIGITALLIMITSWITCHSETTING 9
MOTORCONNECTIONCABLE 12-14
TERMINALDIAGRAM 1516
ELECTRONICBOARDSOVERVIEW 1718
TECHNICALDATA 19
DECLARATIONOFCONFORMITY 19
functioning. The manufacturer declines all responsibility for any
damagescausedbyarbitrarymodicationsintroducedtothede-
vices.
–Donotpositionthedevicesnearsourcesofheatorunprotected
ames.Thiscancausemalfunctioning,reandotherdangers.
–Duringinstallationthedevicesshouldnotbeimmersedinwateror
otheruids.Preventtheinltrationofuidsinthedevicesduring
installation.
–Thepackagingmaterialmustbedisposedofinstrictobservance
of current regulations.
ATTENTION!! – Preserve this manual with utmost care to make
device disposal or maintenance operations easier in the future.