English – 24
Table 5
Switches 1-2 Operation Description
OFF - OFF Manual
(hold-to-run)
the manoeuvre is only executed while the command is active (transmitter button is pressed hold-to-run)
ON - OFF Semiautomatic The sending of a command causes the complete opening or closing manoeuvre to be performed.
CAUTION! - If during the closing manoeuvre, one of the devices connected to the PHOTO input inter-
venes, an 'Automatic Closure' is activated which causes the inversion of the manoeuvre (i.e. Opening),
then a pause and a Closing.
OFF - ON Automatic
(automatic closing)
The sending of a command causes an Opening manoeuvre to be performed, then the system pauses
and then a Closing manoeuvre is performed automatically.
Caution! - If during the pause, one of the devices connected to the PHOTO input intervenes, the
timer is reset with a new value. - If one of the devices connected to the 'STOP' input intervenes, the
re-closing function will be reset and replaced by the 'Stop' status.
ON - ON Automatic + Always
Closes
If, when the power returns following a power failure, the control unit detects the boom is in an Opening
position, it automatically starts a Closing manoeuvre preceded by 5 seconds of pre-ashing.
Note - For 'Semi-automatic', 'Automatic' and 'Automatic + Always Closes' operation:
- if a command to open is sent in hold-to-run mode, when the boom reaches its maximum aperture it will remain blocked until the command
button is released and then it will perform the closing manoeuvre
- if a command to close is sent in hold-to-run mode, when the boom reaches its maximum closure it will remain blocked until the command
button is released and then an opening manoeuvre can be performed
Switch 3 Operation Description
ON
Condominium
(not available in
manual mode)
- When a “Step-by-Step” command is sent and the barrier starts to open, it cannot be stopped by any
other “Step-by-Step” or Open command sent by radio until the manoeuvre has completed.
- Conversely, when the barrier is closing, a new Step-by-Step command will cause the stoppage and
reverse movement.
OFF Disabled
Switch 4 Operation Description
ON
Step-by-step cycle
OPEN - CLOSE - OPEN - CLOSE
OFF OPEN - STOP - CLOSE - STOP
Switch 5 Operation Description
ON
Pre-ashing
When a command is sent, the ashing light starts ashing and, after 5 seconds (2 seconds in Manual
mode), the movement starts.
OFF Disabled
Switch 6 Operation Description
ON
Flashing light
also in pause
The ashing light remains active throughout the manoeuvre and also during the pause to indicate that
a closing manoeuvre is about to occur.
OFF The ashing light remains active only during the manoeuvre (opening or closing)
Switch 7 Operation Description
ON
Close immediately
after 'Photo' (only if
set on 'Automatic'
operating mode)
When set in Automatic mode, it holds the boom open only for the time required for vehicles or pe-
destrians to pass through it; in fact when the Photo safety devices have been cleared, the manoeuvre
stops and after 5 seconds, a Closing manoeuvre starts automatically.
OFF Disabled
Switch 8 Operation Description
ON
'Photo' safety
also in opening
- The intervention of the safety device also causes an interruption to the manoeuvre during Opening.
- When set in 'Semi-automatic' or 'Automatic' modes, the Opening manoeuvre starts again as soon
as the safety devices have been cleared.
OFF The intervention of the safety device causes an interruption to the Closing manoeuvre.
Switch 9 Operation Description
ON One-way trafc
light
The S.C.A. output assumes the function of one-way trafc light:
- Trafc light OFF = when the boom is closed or in the process of closing
- Trafc light ON = when the boom is open or in the process of opening
OFF S.C.A. It indicates the status of the boom
Switch 10 Operation Description
ON Trafc light in both
directions
Function for controlling the ow of vehicles in the two directions using controlled transit of the barrier
mechanism. A different opening command can be set for each trafc direction: 'S. S.' to enter 'S.S.
2' ('Open' input) to leave.
Two trafc lights with 'Red' and 'Green' must be installed and connected to the 'S.C.A.' and 'Courtesy
Light' outputs:
- 'S.S.' Command to enter, the 'SCA' output is enabled = Green light on entry and Red light on exit.
- 'S.S.2' Command to enter, the 'Courtesy Light' output is enabled = Green light on exit and Red light
on entry.
Opening: the light remains active throughout the operation and the subsequent pause.
Closing: 'Green' and 'Red' lights are active at the same time and the result is a light of a 'Yellow'
colour to indicate that there in no specic right of transit