4 Applications
54 Nikon N Series/K Series Total Station Instruction Manual
HA Reset and Angle Operations
To open the Angle menu, press [ANG] in the BMS. To
select a command from this menu, either press the
corresponding number key, or press
[<] or [>] to highlight
the command and then press
[ENT].
Setting the horizontal angle to 0
To reset the horizontal angle to 0, press [1] or select 0-Set in the Angle menu. The
display returns to the Basic Measurement Screen (BMS).
Entering the horizontal angle
To display the HA Input screen, press [2] or select
Input in the Angle menu. Use the numeric keys to
enter the horizontal angle. Then press
[ENT].
Recording a foresight point after repeat angle measurement
1. To activate repeat angle measurement, press [3]
or select
Rept. in the Angle menu.
HR=0 appears.
2. Sight the backsight and press
[ENT].
3. Sight the foresight and press
[ENT].
The horizontal angle is accumulated and the
value is held again.
4. To end repeat angle measurement, press
[ESC].
5. When you have accumulated enough horizontal
angle between the backsight and the foresight,
press
[MSR1] or [MSR2] to take a measurement to
the foresight.
F1 / F2 is not supported by the N 5" and K 5" single face model.
To enter 123°45'50", type [1] [2] [3] [.] [4] [5] [5] [0].
The displayed value is rounded to the minimum angle increment.