4 Applications
60 Nikon N Series/K Series Total Station Instruction Manual
You can delete poor observations and recalculate if necessary. You can also select the
BS point.
1. To start the resection, press
[2] or select
Resection in the Stn Setup menu.
2. Enter the point name for the first observation
point (PT1).
3. Enter the target height and press
[ENT].
4. Sight PT1 and press
[MSR1] or [MSR2].
To use the
F2 softkey for F1/F2 measurements,
see Advanced feature: Measuring F1 and F2,
page 58.
5. To proceed to the next point, press
[ENT].
6. Enter the second point (PT2) and its height of
target.
7. Measure to PT2 and press
[ENT].
When the instrument has enough data, it
calculates the station (STN) coordinates.
If the angle between known point 1 and known point 2 (measured from the station point) is extremely acute or
extremely oblique, the resulting solution will be less reliable geometrically. For geometric reliability, select known
point locations (or station point locations) that are widely spaced.
The F2 softkey is not available on the N 5" and K 5" single face model.

Table of Contents

Other manuals for Nikon N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nikon N Series and is the answer not in the manual?

Nikon N Series Specifications

General IconGeneral
BrandNikon
ModelN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals