3.3.1 Pre-requirements
Equipment necessary for the installation of your heat pump:
Power supply cable suitable for the unit’s power requirements and compliant with your local
regulations.
A By-Pass kit, sufficient PVC tubing suitable for your installation, as well as PVC , PVC
adhesive and sandpaper.
A set of wall plugs and expansion screws suitable to attach the unit to your support or base.
We recommend that you connect the unit to your installation by means of well supported
flexible PVC pipes to reduce the transmission of vibrations.
Suitable fastening studs may be used to raise the unit.
3.3.2 Heat Pump Installation
The heat pump must be fixed using bolts (M10) to a concrete foundation or suitable brackets.
The concrete foundation must be solid; the brackets must be strong enough and treated against
corrosion.
The heat pump needs a water pump (Supplied by the user). Max. lift 30ft;
When the heat pump is running, there will be condensate water discharged from the bottom
that must be properly managed and directed away from the heat pump. Please insert the drainage
tube (accessory) into the hole and clip it in properly, then connect a pipe to drain the condensate
water away. Install the heat pump, at least 3” off the ground with solid, water-resistant pads, then
connect the drainage pipe to the opening located under the heat pump.
3.3.3 Location and Size
Please comply with the following rules concerning the choice of heat pump location.
The unit’s location must be easily accessible for convenient operation and maintenance.
It must be installed on the ground, fixed ideally on a level concrete floor. Ensure that the floor
is sufficiently stable and can support the weight of the unit.
A water drainage device must be provided close to the unit in order to protect the area where
it is installed.
If necessary, the unit may be raised by using suitable mounting pads designed to support its
weight.
Check that the unit is in a properly ventilated area, that the air outlet is not facing the windows
of neighboring buildings and that the exhaust air cannot return to the heat pump. In addition,
provide sufficient space around the unit for servicing and maintenance operations.
The unit must not be installed in an area exposed to oil, flammable gases, corrosive products,
sulfur compounds or close to high frequency equipment.