H5CR H5CR
3
Memory function Retains preset values for 10 years at 25° C (77° F)
Materials Plastic case
Mounting Panel or surface; Y92F-30 Panel, Y92F-30 mounting bracket included
mounting bracket included
Connections 8-pin round socket Screw terminals
Weight 105 g (3.7 oz.) 160 g (5.6 oz.) 120 g (4.2 oz.)
Approvals UL/CSA/SEV
Operating ambient temperature -10° to 55°C (14° to 131°F) with no icing
Humidity 35% to 85% RH
Vibration Mechanical durability 10 to 55 Hz with 0.75 mm single amplitude in 3 directions
Malfunction durability 10 to 55 Hz with 0.5 mm single amplitude in 3 directions
Shock Mechanical durability 30 G each in three directions
Malfunction durability 10 G each in three directions
Variation due to voltage change Included in "Repeat accuracy" specification
Variation due to temperature change Included in "Repeat accuracy" specification
Insulation resistance 100 M min. at 500 VDC between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts.
Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
Service life Mechanical 10 million operations minimum
(SPDT relay) Electrical 100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
SPECIFICATIONS continued
Timing Charts
OPERATION MODES
The gate input is not included on "economy" models H5CR-L and H5CR-LS.
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
Timing begins at the leading edge of
the start signal. The control output will
be energized when the present value
equals the preset time. The output will
be sustained until a reset signal is
applied, until power is interrupted, or
for a programmable one-shot time
period.
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Timing begins at the leading edge of the
start signal. The control output will be
energized if the start signal is sustained
for an amount of time equal to the preset
time. The output will be sustained until
the start signal is interrupted, until a reset
signal is applied, until power is
interrupted, or for a programmable one-
shot time period.
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Power
Start signal
Set value
UP 0
Gate
Reset
Control output
Set value
DOWN 0
Timing
diagram
Timing
diagram
Sustained output
One-shot
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, and 20 s.