3-87
3 Error Tables
NJ-series Troubleshooting Manual (W503)
3-1 Errors by Source
3
3-1-7 Errors in Slave Terminals
The section provides tables of the errors (events) that can occur in the following Units in OMRON Slave
Ter mi nals.
NX-series EtherCAT Coupler Units
NX-series Digital I/O Units
NX-series Analog I/O Units
NX-series System Units
NX-series Position Interface Units
NX-series Safety Control Units
54013012 hex
(Ver. 1.05)
DB Connec-
tion Instruc-
tion
Execution
Timeout
The instruction was
not completed
within the time
specified for time-
out.
The power supply to the server
is OFF.
The Ethernet cable connector is
disconnected.
The Ethernet cable is broken.
The server’s processing time is
long.
S NJ-series
Database
Connection
CPU Units
User’s Manual
(Cat. No.
W527)
54013013 hex
(Ver. 1.05)
DB Connec-
tion Service
Error Stop
The instruction
could not be exe-
cuted because the
DB Connection
Service was
stopped due to an
error.
The DB Connection settings
are corrupted.
S Same as
above.
54013014 hex
(Ver. 1.05)
Data Already
Spooled
One or more SQL
statements are
already stored in
the Spool memory.
A DB_Insert or DB_Update
instruction was executed when
one or more SQL statements
were already stored in the
Spool memory.
A DB_Select or DB_Delete
instruction was executed when
one or more SQL statements
were already stored in the
Spool memory.
S Same as
above.
54013015 hex
(Ver. 1.05)
DB Connec-
tion Service
Initializing
The instruction
could not be exe-
cuted because the
initialization pro-
cessing of the DB
Connection Ser-
vice is in progress.
The relevant instruction was
executed during the initializa-
tion processing of the DB Con-
nection Service.
S Same as
above.
54013016 hex
(Ver. 1.05)
DB in Pro-
cess
The instruction
could not be exe-
cuted because the
DB is under pro-
cessing in the
server.
Though a DB Connection
Instruction Execution Timeout
occurred for the previous
instruction, the relevant instruc-
tion was executed before com-
pletion of the DB’s processing
in the server.
S Same as
above.
54013017 hex
(Ver. 1.05)
Operation
Log Disabled
The log could not
be recorded
because the speci-
fied Oper
ation Log
is disabled.
Th
ough Execution Log was
specified in the LogType input
variable, the Execution Log is
disabled.
Though Debug Log was speci-
fied in the LogType input vari-
able, recording to the Debug
Log is stopped.
S Same as
above.
3-1-7 Errors in Slave Terminals
Event code Event name Meaning Assumed cause
Level
Reference
Maj Prt Min Obs Info

Table of Contents

Other manuals for Omron NJ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NJ Series and is the answer not in the manual?

Omron NJ Series Specifications

General IconGeneral
BrandOmron
ModelNJ Series
CategoryController
LanguageEnglish

Related product manuals