Unit Versions
20
NX-series Safety Control Unit Instructions Reference Manual (Z931)
The following information is provided in the notched area on the Unit.
You can use the Unit Production Information on the Sysmac Studio to check the unit versions EtherCAT
Coupler Unit and NX Units.
1 Double-click EtherCAT under Configurations and Setup in the Multiview Explorer, and then
double-click the EtherCAT Coupler Unit. Or, right-click the EtherCAT Coupler Unit and select
Edit from the menu.
The Edit Slave Terminal Configuration Tab Page is displayed.
You can also display the Edit Slave Terminal Configuration Tab Page with any of the following
operations.
Double-click EtherCAT under Configurations and Setup in the Multiview Explorer, right-click
the EtherCAT Coupler Unit in the EtherCAT Configuration Edit Tab Page, and select Edit Slave
Terminal Configuration.
Or, select the EtherCAT Coupler Unit on the EtherCAT Configuration Edit Tab Page click the
Edit Slave Terminal Configuration Button.
2 Go online.
3 Right-click the EtherCAT Coupler Unit and select Display Production Information from the
menu.
The Production Information Dialog Box is displayed.
In this example, “Ver.1.0” is displayed next to the Unit model.
The following items are displayed.
• Slot number
• Unit model number
• Unit version
• Serial number
• Lot number
Name Function
Lot number and
unit version
Gives the lot number and unit version of the Unit.
• DDMYY: Lot number, : Used by OMRON.
“M” gives the month (1 to 9: January to September, X: October, Y: November, Z: December)
•1: Unit version
The decimal portion of the unit version is omitted. (It is provided in the Unit specifications.)
Confirming Unit Versions with the Sysmac Studio
Simple Display
Detailed Display