2 Standard Functions
2 - 50
NX-series Safety Control Unit Instructions Reference Manual (Z931)
WORD_TO_BOOL
This function converts a WORD variable to a BOOL variable.
If you omit an input or output parameter, a building error will occur.
This function converts WORD data In to BOOL data Out.
If the value of In is WORD#16#0000, the value of Out is FALSE.
If the value of In is WORD#16#0001 to WORD#16#FFFF (i.e., not WORD#16#0000), the value of Out
is TRUE.
To convert BOOL data to WORD data, refer to BOOL_TO_WORD.
• The input condition depends on whether the output is safety data or standard data. If the condition is
not met, a building error will occur.
• If you set a safety data type variable for the output terminal, set a safety data type variable for the
input terminal as well.
• If you set a standard data type variable for the output terminal, you can set either a safety data type
variable or a standard data type variable for the input terminal.
• If the input value is not WORD#0 or WORD#1, a cast error will occur and the program will stop.
Instruction Name FB/FUN Graphic expression
WORD_TO_BOOL Convert WORD
to BOOL
FUN
Variables
Name I/O Description Valid range Default
In Data to con-
vert
Input Data to con-
vert
WORD#16#0000 to FFFF WORD#16#0000
Out Conversion
result
Output Conversion
result
TRUE or FALSE FALSE
Boolean Bit strings Integers Durations
BOOL
SAFEBOOL
BYTE
SAFEBYTE
WORD
SAFEWORD
DWORD
SAFEDWORD
INT
SAFEINT
DINT
SAFEDINT
TIME
SAFETIME
In OK OK
Out OK OK
Function
Additional Information
Precautions for Correct Use