4 Safety Function Blocks
4 - 128
NX-series Safety Control Unit Instructions Reference Manual (Z931)
8005 32773 Button 1 Actuated Only Button1 is being operated.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
8006 32774 Button 2 Actuated Only Button2 is being operated.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
8007 32775 Button 2 Released The safety output was enabled and then disabled
again. After the safety output was disabled,
S_Button1 and S_Button2 did not both change to
FALSE. In this state, S_Button1 is TRUE and
S_Button2 is FALSE after the safety output is dis-
abled.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
8008 32776 Button 1 Released The safety output was enabled and then disabled
again. After the safety output was disabled,
S_Button1 and S_Button2 did not both change to
FALSE. In this state, S_Button1 is FALSE and
S_Button2 is TRUE after the safety output is dis-
abled.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
8009 32777 Locked Off The safety output was enabled and then disabled
again. After the safety output was disabled,
S_Button1 and S_Button2 did not both change to
FALSE. In this state, S_Button1 is TRUE and
S_Button2 is TRUE after the safety output is dis-
abled.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
8019 32793 Locked On The button operation was not correct. The FB is
waiting for both buttons to be released.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name Status description and output results