9 - 129
9 Details on Servo Parameters
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
9-16 General-purpose Output Setting Objects
9
9-16-17 465F hex: Zone Notification Output 1
Sets the Zone Notification Output 1 (ZONE1).
Sets the Zone Notification Output 2 (ZONE2).
Sets the Position Command Status Output (PCMD).
9-16-17 465F hex: Zone Notification Output 1
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes of
operation
465F --- Zone Notification
Output 1
--- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Port Selection 0 to 7 --- 0 R 4 bytes
(INT32)
RW --- --- ---
02 Logic Selection 0 to 1 --- 0 R 4 bytes
(INT32)
RW --- --- ---
81 Signal Status --- --- --- --- 4 bytes
(INT32)
RO --- --- ---
9-16-18 4660 hex: Zone Notification Output 2
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes of
operation
4660 --- Zone Notification
Output 2
--- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Port Selection 0 to 7 --- 0 R 4 bytes
(INT32)
RW --- --- ---
02 Logic Selection 0 to 1 --- 0 R 4 bytes
(INT32)
RW --- --- ---
81 Signal Status --- --- --- --- 4 bytes
(INT32)
RO --- --- ---
9-16-19 4661 hex: Position Command Status Output
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes of
operation
4661 --- Position Com-
mand Status Out-
put
--- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Port Selection 0 to 7 --- 0 R 4 bytes
(INT32)
RW --- --- ---
02 Logic Selection 0 to 1 --- 0 R 4 bytes
(INT32)
RW --- --- ---
81 Signal Status --- --- --- --- 4 bytes
(INT32)
RO --- --- ---