4 - 15
4 System Design
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
4-2 Wiring
4
4-2-1 Peripheral Equipment Connection Examples
R88D-KN01H-ECT-L/-KN02H-ECT-L/-KN04H-ECT-L/
-KN08H-ECT-L/-KN10H-ECT-L/-KN15H-ECT-L (3-phase Input)
1MC
OFF ON
X
1MC
1MC
X
PL
RT
NFB
S
123
456
E
NF
L1C
L2C
L1
L2
L3
ALMCOM
/ALM3
4
X
24 VDC
1
2
OUTM1
(BKIR)
OUTM1
COM
XB
24 VDC
W
V
U
CN4
(*3)
CN1
CN1
B1
B3
B2
(*4)
CNB
CNB
CNA
CNA
X
ECAT
IN
OUT
LM
Main circuit
power supply
Main circuit contactor (*1)
Surge suppressor (*1)
G5-series AC Servo Drive
User-side
control
device
Noise filter (*1)
Ground to
100 Ω or less
3-phase 200 to 240 VAC, 50/60 Hz
Servo error display
External encoder
cables
Power cables (*2)
*1. A recommended product is listed in 4-3,
Wiring Confirming to EMC Directives.
*2.
Do not use shielded cables for power cables.
*3. Recommended relay: MY relay by OMRON
(24 VDC 2A)
Select one that matches the ratings of the
brake etc. to be used.
*4. Models with a built-in Regeneration Resistor
(KN08H-ECT-L to KN15H-ECT-L) have B2
and B3 shorted. When the amount of
regeneration is large, remove the connection
between B2 and B3 and connect the
Regeneration Resistor between B1 and B2.
Regeneration
resistor
Reactor
Motor
coil unit
External
encoder
Ground to
100 Ω or less
General-purpose
inputs 1 to 8
External sensor, etc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN30F-ECT-L and is the answer not in the manual?

Omron R88D-KN30F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN30F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals