11 Adjustment Functions
11 - 32
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
11-10Feed-forward Function
The feed-forward function come in 2 types: speed feed-forward and force feed-forward.
The speed feed-forward can minimize the Following Error Actual Value and increase the
responsiveness during the position control.
Responsiveness is improved by adding the speed feed-forward value calculated from the internal
position command and related objects (3110 hex and 3111 hex) to the speed command calculated by
comparing the internal position command and the position feedback.
If the Velocity offset (60B1 hex) is set, both the set value and the speed feed-forward valued are added
to the Control effort (60FA hex).
The force feed-forward can increase the responsiveness of the speed control system.
Responsiveness is improved by adding the force feed-forward value calculated from the Control effort
(60FA hex) and related objects (3112 hex and 3113 hex) to the force command calculated by
comparing the Control effort (60FA hex) and the speed feedback.
If the Torque offset (60B2 hex) is set, both the set value and the force feed-forward valued are added to
the force command.
11-10-1 Objects Requiring Settings
Index Name Description Reference
3110 hex Speed Feed-forward Gain The speed command from position control processing is
added to the product of the Control effort (60FA hex) that
is calculated from the internal position command times
the ratio in this object.
P. 9-10
3111 hex Speed Feed-forward
Command Filter
Set the time constant for the first-order lag filter that is
applied to speed feed-forward input.
P. 9-10
3112 hex Force Feed-forward Gain The force command from speed control processing is
added to the product of the Control effort (60FA hex)
times the ratio in this object.
P. 9-10
3113 hex Force Feed-forward
Command Filter
Set the time constant for the first-order lag filter that is
applied to force feed-forward input.
P. 9-11
60B1 hex Velocity offset Set the offset for the speed command.
It will be added to the Control effort (60FA hex).
P. A-68
60B2 hex Torque offset Set the offset for the force command.
This object corresponds to the Force Feed-forward object
in Cyclic synchronous position mode (csp) or Cyclic
synchronous velocity mode (csv).
It will be added to the force command value.
P. A-69

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN30F-ECT-L and is the answer not in the manual?

Omron R88D-KN30F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN30F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals