12 Troubleshooting and Maintenance
12 - 26
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
91 hex 1 hex Command Error Occurs
during
operation.
• When bit 9 (Remote) of the
Statusword (6041 hex) was set
to 1 (remote), and the Servo
Drive was in operation enabled
status (Servo ON), a command
that changes the
communications status from
Operational to another status
(Init, Pre-Operational,
Safe-Operational) was
received.
• An unsupported number was
set for the Modes of operation
(6060 hex).
• The setting of the Modes of
operation (6060 hex) was
changed at an interval of less
than 2 ms.
• The homing operation was
started when the Homing
method (6098 hex) is set to
other than 8, 12, 19, 20, 33, 34,
and 35.
• The Data Setting Warning
(Warning No. B0 hex) occurred
in a row, exceeding the Data
Setting Warning Detection
Setting (3781 hex) value.
Check the command
specifications of the host
controller.
Error No.
Name
Error
timing
Cause Measures
Main Sub

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN30F-ECT-L and is the answer not in the manual?

Omron R88D-KN30F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN30F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals