2.2 Specifications
Maximum log length
1
20 in (508 mm) east-west
Flue outlet diameter 6 in (150 mm)
Recommended connector pipe diameter 6 in (150 mm)
Type of chimney ULC S629, UL 103HT (2100 °F)
Baffle material C-Cast
Approved for alcove installation Yes
Approved for mobile home installation
2
Yes
Shipping weight (without option) 390 lb (177 kg)
Appliance weight (model with legs) 368 lb (167 kg)
Appliance weight (model with pedestal) 377 lb (171 kg)
Type of door Simple, glass with cast iron frame
Type of glass Ceramic glass
Blower Included (up to 130 CFM)
Particulate emission standard EPA / CSA B415.1-10
3
USA standard (Safety) UL 1482, UL 737
Canada standard (Safety) ULC S627
1
East-west: through the door you see the longitudinal sides of the logs; north-south: through the door you see the tips of the logs.
2
Mobile home (Canada) or manufactured home (USA): The US department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as followed; buildings built on xed wheels and those transported on temporary wheels/axles and set on a
permanent foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or
substantially completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the
CAN/CSA-Z240 MH standard.
3
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and Draft ASTM WK47329-14.