34 COOLING CAPACITY PERFORMANCE DATA
Model Power Source Entering Temperature Air Entering Condeser (°C D.B.)
(CS-) AIR 25 °C 30 °C 35 °C 40 °C 43 °C
Temperature TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW
A18BB4P 220V, 17 5.21 3.41 1.51 5.00 3.38 1.64 4.71 3.27 1.78 4.35 3.13 1.96 4.10 3.03 2.07
50Hz, 23 19 5.50 2.80 1.60 5.33 2.82 1.74 5.05 2.78 1.89 4.71 2.69 2.07 4.47 2.64 2.20
Single phase 22 6.00 2.16 1.73 5.84 2.22 1.87 5.57 2.23 2.04 5.22 2.19 2.24 4.97 2.19 2.38
17 5.14 3.93 1.51 4.94 3.88 1.64 4.66 3.75 1.78 4.32 3.61 1.94 4.08 3.48 2.06
25 19 5.50 3.47 1.61 5.31 3.45 1.74 5.03 3.37 1.90 4.68 3.25 2.07 4.44 3.17 2.19
22 6.00 2.73 1.74 5.82 2.76 1.88 5.53 2.74 2.05 4.96 2.56 2.24 4.92 2.63 2.37
17 5.08 4.52 1.52 4.89 4.45 1.63 4.61 4.29 1.78 4.29 4.12 1.93 4.06 4.02 2.05
27 19 5.51 4.08 1.62 5.30 4.03 1.75 5.00 3.90 1.90 4.65 3.77 2.07 4.40 3.65 2.19
22 5.99 3.30 1.75 5.79 3.30 1.89 5.49 3.24 2.05 4.71 2.87 2.23 4.88 3.07 2.36
17 5.07 4.97 1.51 4.89 4.84 1.63 4.41 4.41 1.76 4.32 4.32 1.89 4.11 4.11 1.97
29 19 5.50 4.67 1.61 5.30 4.61 1.74 4.79 4.26 1.88 4.69 4.29 2.02 4.45 4.19 2.10
22 5.97 3.91 1.77 5.77 3.89 1.92 5.22 3.63 2.07 4.95 3.56 2.22 4.87 3.61 2.31
17 5.06 4.96 1.50 4.89 4.89 1.63 4.28 4.28 1.74 4.34 4.34 1.86 4.14 4.14 1.91
32 19 5.49 5.44 1.60 5.30 5.30 1.74 4.65 4.65 1.86 4.71 4.71 1.98 4.49 4.49 2.04
22 5.96 4.88 1.79 5.75 4.83 1.94 5.04 4.33 2.08 5.11 4.55 2.21 4.87 4.43 2.28
Legend:
TC = Total Cooling Capacity
SHC = Sensible Heat Capacity
IPT = Power Consumption
Model Cooling capacities are based on conditions below.
CS-A18BB4P 1 phase, 50Hz, 220V
Cooling capacity Indoor temp. 27°C D.B. 19°CW.B.
5.0kW Outdoor temp. 35°C D.B.
Standard air volume 14 m
3
/min
112 [MAICO] Printed in Malaysia