Parker Hannin Corporation
Pressure uids
The following rules applies for the operation with
various pressure uids:
This information serves for orientation and
does not substitute user tests among the
particular operating conditions. Particularly
no liabiliy for media compatibility may be
derived out of it.
Mineral oil: usable without restriction.
For operation with the following pressure uids
please consult Parker:
For detailed information concerning pressure
uids note VDMA-document 24317 as well as
DIN 51524 & 51502.
Special gaskets may be available depending on
the utilized uid.
In case of insecurity please consult Parker.
The pressure uid must have an ignition tempera-
ture of at least 50 K above the maximum surface
temperature of the valve (see EN 13463-5 and IEC
60079-4).
Electrical connection
Observe operating instructions D14-2128D3-* and
K14-2074D3-* in the annex.
Operation limits
The valve may only be deployed with the specied
limits of use. The relevant details can be found in
the catalogue sheet under "Technical data" and
"Characteristic curves".
Observe the ambient conditions. Unau-
thorised temperatures, shocks, the eects
of aggressive chemicals, radiation, unau-
thorised electromagnetic emissions may
result in disruptions and failures. Observe
the limits of operation set out in "Technical
data".
Excessive temperatures may cause the so-
lenoid to overheat, creating the risk of ex-
plosion. To permit adequate heat dissipati-
on, the solenoid coil should not be painted.
Size 6, mounting pattern ISO 4401-03-03-0-05
HFA oil-in-water emulsion
HFB water-in-oil emulsion
HFC aqueous solution (glycols)
HFD unhydrous uids (Phosphor-Ester)