PGI 1200 B2
GB │ 19 ■
Troubleshooting
Fault Cause Measure
Engine cannot be started. Automatic oil switch-off activates. Check oil level, add engine oil.
Soot deposit on spark plug
. Clean or replace spark plug .
Electrode gap at 0.6 mm.
No fuel.
Add fuel / check fuel tap
.
Generator has too little or no voltage. Electronics defective. Contact specialist retailer.
Overvoltage safety switch has been
triggered.
Restart generator, reduce consumers.
Air filter
soiled.
Clean or replace filter.
Maintenance schedule
The following maintenance schedule must be complied with to ensure trouble-free operation.
CAUTION!
► Before first use, engine oil and fuel must be filled in.
Before every use after 20 hours of
operation
after 50 hours of
operation
after 100 hours of
operation
after 300 hours of
operation
Check the
engine oil
X
Change the
engine oil
for the first time,
and then
every 50 hours
X
Check the
air filter
X
replace filter pad
if necessary
Clean the
air filter
X
Clean the
fuel filter
X
Visual inspection
of the appliance
X
Clean the
spark plug
Gap: 0.6 mm,
replace if
necessary
Check and
adjust the
throttle valve
X*
Clean the
cylinder head
X*
Set the valve
clearance
X*
ATTENTION: Points marked "X*" may only be carried out by an authorised specialist workshop.