94
Zeroize the Security Key
1
Pull down the zeroize latch on the top of the unit.
2
With the zeroize latch held down, twist the Power Knob counterclockwise from the OFF
position to the Z position.
Note: the status indicator LED will blink red once when the key is zeroized.