III. Product overview and installation illustration
2
Maximum inlet water
hardness
25 °HF***
Applicable water source
Municipal tap water, which meets all European
Directive on Water for Human Consumption 98/83
requirements and its national transpositions in
the various EU member states.
** When the inlet water pressure exceeds 0.4 MPa, a pressure relief valve should
be installed before the system. When the inlet water pressure is below 0.1 MPa,
a pressure booster should be installed before the system. The pressure relief valve
and extra pressure booster need to be purchased separately.
*** If the salinity of inlet water exceeds 1500 ppm, or the hardness exceeds 25 °HF,
the lifetime of the lters may be impacted. Please consult with your dealer about
installing prefilters before the system.
Sediment and carbon block filter 2-in-1 (CP)
2
1
Cover
Reverse osmosis lter (RO)
3
System
4
Faucet and accessory
5
Quick connect fitting
6
7
Three-way ball valve
1/4” PE pipe
8
3/8” PE pipe
9
Leakage detector
10
Power adapter with plug
11
Drain connector
12
1
2
3
4
5
1110
6
9
12
7
8