01_44
CORRECT PROGRAMMING CHECK PHASE
When the programming of the codes was successful, the switching to «ON» with the
MASTER key «A» causes the start of the immobilizer warning light for a time interval
of about 0.7 s and then a short flashing number equal to the number of keys inserted
in the programming, including the MASTER key itself.
Pull the «MASTER» key «A» out, then insert it again disabling the transponder
«C» (i.e., by tilting the key cap by 90°), and switch to «ON». When performing the
starter operation, ensure that the engine does not start.
Insert the programmed key «B» and switch to «ON». When the programming was
successful, the immobilizer warning light turns on for one single time interval of about
0.7. When performing the starter operation, ensure that the engine starts.
WARNING
SHOULD YOU START THE ENGINE WITH THE MASTER KEY (WITH TRANS-
PONDER OFF) OR IN THE EVENT OF WRONG OPERATION DURING PROGRAM-
MING, REPEAT THE PROCEDURE FROM THE BEGINNING.
01_45
Accessing the fuel tank (01_45, 01_46)
To open the fuel tank cover, set the ignition switch to «OFF» or « ON», then press
and turn it clockwise.
CAUTION
ALWAYS USE PETROL WITH A MAXIMUM OF 10% BIOETHANOL CONTENT
(E10).
39