- 23 -
GB
of ice inside the food, which would lead to the loss of liquids
and vitamins.
This cycle is suitable for both cooked and fresh foods,
which can be then kept for up to 2 months and up to 12
months respectively.
Holding cycle:
At the end of every chilling or freezing cycle, the machine
switches to a holding cycle, during which it functions like
a normal refrigerator. The duration of this cycle can be set
at the user’s discretion.
STORING FOODS
The following rules are fundamental in obtaining the best
performance from your cold storage appliance:
Holding cycle
- Never place hot foods or uncovered liquids inside;
- Wrap or otherwise protect foods, particularly if they
contain herbs or spices;
- Try to open the door as infrequently as possible, and
do not leave it open.
Blast chilling/shock freezing cycle
- Once the cycle has started, do not open the door until
it is completed;
- Never wrap, protect or close portions with lids or
insulating films;
- Never use portions or containers more than 65 mm
high;
- Never stack foods;
- Use containers in aluminium or stainless steel.
3.2 ANY HAZARDOUS AREAS, RISKS, HAZARDS AND
UNAVOIDABLE RISKS
Our cold storage appliances are designed to assure the
user’s health and safety.
We guarantee their stability even when the appliance doors
are open - do not hang onto the doors, this is strictly
forbidden. Our appliances do not have any hazardous
corners, sharp edges or projections.
RISKS DUE TO MOVING PARTS
The only moving part is the fan, which offers no risk since
it is protected by a grille screwed in place (before removing
this grille, disconnect the appliance from the power supply).
RISKS DUE TO EXTREME TEMPERATURES
Warning stickers marked “high temperature” are applied
near to zones where high temperatures may occur. Before
removing trolleys or pans at the end of the freezing cycle,
always put on gloves since the temperature is extremely
low.
RISKS DUE TO ELECTRICITY
Risks of an electrical nature have been overcome by
designing the electrical systems in accordance with CEI
EN 60204-1. Stickers warning “high voltage” mark the areas
where there is an electrical hazard.
RISKS DUE TO NOISE
Leq < 70 dB(A)
Lpc < 130 dB(C)
REMAINING RISKS
The storage unit is not equipped with a drainage facility,
therefore after every temperature reduction or freezing
cycle, carefully clean the interior to avoid stagnating
liquids.
3.3 SAFETY DEVICES ADOPTED
The storage unit has a safety handle located inside the
door.
A luminous adhesive sticker (it becomes luminous in the
dark after exposure to a natural or artificial light source)
is affixed near to the handle. This enables anyone inside
the storage unit to identify the exit safety handle.
The appliance is provided with a trolley bearing structure
plus a trolley.
This structure was designed in order to prevent locating
the trolley directly inside the storage unit, since the
trolley wheels could introduce bacteria to the storage
unit thus jeopardising hygiene.
CAUTION: TAMPERING WITH OR REMOVAL OF THE
SAFETY DEVICES ADOPTED IS
ABSOLUTELY FORBIDDEN. THE
MANUFACTURER DECLINES ALL
RESPONSIBILITY IN CASE OF FAILURE TO
COMPLY WITH THESE INSTRUCTIONS.