Page 22
ENG
ENG
P91 SERIES
2. Remove three (3) screws from cable
receptacle (see Figure 6). Remove the
Floating Cable and receptacle.
3. Check inside the receptacle for water
damage.
4. Perform a complete visual inspection of the
length of the entire Floating Cable for wear.
5. Check the power plug for any visible wear or
water damage.
Page 22
6. Check the O-ring for damage.
7. If there is no evidence of water damage to the
O-ring, the cable receptacle, or the Floating
Cable and power plug, the motor block is
defective. Replace with a new motor block
and repeat the test.
NOTE Return defective component(s) to Polaris.
(For more information, go to
www.Polarispool.com.)