93 94 95 SERIES
2.3 Perform Test for Defective
Motor Block
1. Unplug the cleaner.
2. Open the cleaner top and remove the lter
canister. Remove the screw securing the
propeller guard and remove propeller guard.
3. Remove the propeller and the ow director by
pushing out toward rear of cleaner housing.
Remove the Propeller Guard
Remove the Propeller and Flow Director
4. Close the cover, turn cleaner over and place
on a soft surface so that it is resting on its top.
5. Remove four (4) screws from the bottom of
the cleaner. Remove the bottom plate/motor
block.
NOTE When removing the motor block, ensure the
drive gears and drive pins are on the drive shafts.
Remove the four (4) Motor Block Screws
6. Disconnect the Floating Cable from the motor
block by removing two (2) screws connecting
the cable to the block. Pull the plug away from
the block to remove.
NOTE You will have one of the following motor
block cable plugs:
Integral Seal Plug
O-Ring Plug
(Take care not to lose or remove the O-ring)