Proton Products InteliSENS DG2030 Diameter Gauge Instruction Manual (Issue 1a)
ANALOGUE INPUT
The analogue input may be connected to a 0 to +10V signal from a line speed gauge.
Measured line speed input is required for:
Helix mode operation.
PI feedback controller operation.
Statistical Process Control (SPC) operation.
Analogue input connection
If installed, the analogue input may be accessed through the “INTERFACE connector.
Connector type: DB25 female (socket)
Pin
Designation
Description
9
AGND
Analogue input ground
22
AIP
Analogue input
S
Shield
Analogue input electrical specifications
The analogue input and its ground reference are isolated from earth.
Specification
Minimum
Typical
Maximum
Units
Input voltage measurement range
0
+10
V
Input voltage absolute range
-35
+35
Input-to-earth voltage
-50
+50
V
Input resistance
8
kΩ