Proton Products InteliSENS DG2030 Diameter Gauge Instruction Manual (Issue 1a)
DW Bit Comments Unit Range/Remark Default value
DW25
DW26
Preset Z lower limit 1=0.01um/0.01mil 0~20000000 50000
DW27
DW28
Preset Ovality upper limit 1=0.01um/0.01mil 0~20000000 50000
DW29
DW30
Preset Ovality lower limit 1=0.01um/0.01mil 0~20000000 50000
DW31
DW32
Preset SMFD upper limit
1=0.01um/0.01mil/
1=0.1%
0~20000000 50000
DW33
DW34
Preset SMFD lower limit
1=0.01um/0.01mil/
1=0.1%
0~20000000 50000
DW35
DW36
Preset core diameter 1=0.01um/0.01mil 0~20000000 800000
DW37
DW38 Diameter Average time 1=1ms 0~5000 1000
DW39 Shrinkage
0~10000 0
DW40 Pitch for helix 1=10um{1=1mil) 1~65535 1000
DW41 Core number for helix 1=1 1~100 2
DW42 Flaw interval time
1=0.001s/1=0.001m{1
=0.001ft}
1~65535 100
DW43
SMFD reference diameter
average time
1=1ms 1~1000 100
DW44
SMFD measurement
average time
1=0.1ms 1~100 10
DW45
Start speed for SMFD
detection
1=1m/min{1=1ft/min} 1~65535 0
DW46 Start Length for SMFD 1=1m{ft} 0
DW47
Start Length for Diameter
over tolerance
1=1m{ft} 0
DW48
maximum and minimum
1=Reset;other=Invalid 0
DW49
Logic input
0
Logic input 1 function
Alarm 1;2=External
Alarm 2;3=Line rev
0
1
2
Logic input 2 function
Alarm 1;2=External
Alarm 2;3=Line rev
1
3
4 The polarity of logic input 1
0=Active low; 1=Active
high
0
5 The polarity of logic input 2
0=Active low; 1=Active
high
0
DW50
Relays
0
Relay 1 function
0=Gauge OK;1=Over
all limit; 2=Under all
limit;3=Flaw;4=Lump;5
=Neck, 6=Over
Average Upper
0
1
2