QS3.241
Q-Series
24V, 3.4A, SINGLE PHASE INPUT
Jul. 2020 / Rev. 2.3 DS-QS3.241-EN
All parameters are specified at 24V, 3.4A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
13/26
The power supply is suitable for applications in industrial environment as well as in residential, commercial and light
industry environment without any restrictions.
The CE mark indicates conformance with the EMC directive 2004/108/EC, the low-voltage directive (LVD) 2006/95/EC
and the RoHS directive 2011/65/EC. A detailed EMC report is available on request.
munity
According generic standards: EN 61000-6-1 and EN 61000-6-2
EN 61000-4-2
contact discharge
air discharge
8kV
15kV
Criterion A
Criterion A
EN 61000-4-3 80MHz-2.7GHz 10V/m Criterion A
(Burst) EN 61000-4-4
input lines
output lines
4kV
2kV
Criterion A
Criterion A
EN 61000-4-5
L N
L PE, N PE
2kV
4kV
Criterion A
Criterion A
EN 61000-4-5
+ -
+ / - PE
1kV
1kV
Criterion A
Criterion A
EN 61000-4-11
0% of 100Vac
40% of 100Vac
70% of 100Vac
0% of 200Vac
40% of 200Vac
70% of 200Vac
0Vac, 20ms
40Vac, 200ms
70Vac, 500ms
0Vac, 20ms
80Vac, 200ms
140Vac, 500ms
Criterion A
Criterion C
Criterion A
Criterion A
Criterion A
Criterion A
EN 61000-4-11 0% of 200Vac (=0V) 5000ms Criterion C
dips on the input voltage according to SEMI F47 standard
80% of 120Vac (96Vac)
70% of 120Vac (84Vac)
50% of 120Vac (60Vac)
1000ms
500ms
200ms
Criterion A
Criterion A
Criterion A
VDE 0160 over entire load range 750V, 1.3ms Criterion A
Criterions:
A: Power supply shows normal operation behavior within the defined limits.
C: Temporary loss of function is possible. Power supply may shut-down and restarts by itself. No damage or hazards for the power supply
will occur.
According generic standards: EN 61000-6-3 and EN 61000-6-4
EN 55011, EN 55032, FCC Part 15, CISPR 11, CISPR 32 Class B
**)
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1
limits for DC power port acc. EN
61000-6-3 not fulfilled
EN 55011, EN 55032 Class B
c input current EN 61000-3-2 fulfilled for class A equipment
Voltage fluctuations, flicker
EN 61000-3-3 fulfilled *)
his device complies with FCC Part 15 rules.
Operation is subjected to followin
g two conditions: (1) this device may not cause harmful interference, and (2) this
st accept any interference received, including interference that may cause undesired operation.
*) tested with constant current loads, non pulsing
**) for information only, not mandatory for EN 61000-6-3
Frequency 65kHz to 270kHz input voltage and load dependent