17
CHC1102M GB F - REV005B
GB
Use keys
p
and q(UP and DOWN) to select the data items within the menu.
The data item that has been currently selected appears in reverse.
Use key
=
(SELECT) to confirm the selected data item.
SETTING THE CHAIN COUNTER
The chain counter has a several functions that can be personalized to satisfy user's
requirements.
To go to the setting menu, press and release key
=
(SELECT) (the monitoring line will
start to flash after the button has been pressed)for more than 3 seconds.
As soon as the key is released a window similar to the one shown below is displayed:
SETTINGS
COUNTER RESET
FUNCTIONS
PERSONAL SET
DATE AND TIME
LANGUAGE
CALIBRATION
The following data items are provided on the settings menu, with the MASTER chain
counter present on the network:
The structure
of the menus:
COUNTER RESET
FUNCTIONS
PERSONAL SET
DATE AND TIME
LANGUAGE
CALIBRATION
AUTO CALIBRATE
UTILITY
CAN CONFIG
EXIT
UP ALARM
AUTO DOWN
CONTRAST
LIGHT
LIGHT DELAY
KEY BEEP
LOCKED KEYS
ENGLISH
ITALIANO
FRANCAIS
DEUTSCH
ESPANOL
SET MEASURE
GYPSY LAP
MAGNETS NUMBER
FREE FALL
SENSOR TEST
LCD TEST
CLOCK BATTERY
SW VERSION
SET DEFAULT
CHECK FLASH
CHECK EEPROM
CAN MESSAGE
DATA ITEM
COUNTER RESET
FUNCTIONS
PERSONAL SET
DATE AND TIME
LANGUAGE
CALIBRATION
AUTO CALIBRATE
UTILITY
CAN CONFIG
EXIT
SYNTHETIC DESCRIPTION
Reset the measure of chain lowered.
Automatic down and up alarm setting.
Chain counter personalization: contrast, back-lighting, light delay, key beep, timed locking of the
p
and
q
(UP and
DOWN) keys.
System date and time setting.
Language used for system messages.
Chain counter calibration: setting of the measurement unit, of the number of magnets installed, of the gypsy lap on
the gypsy and management of the windlass with free fall.
Automatic chain counter calibration.
Various chain counter controls.
MASTER/SLAVE setting if more than one chain counter is used.
Chain counter set-up menu exit.
SETTING THE CHAIN COUNTER