30
CHC1102M GB F - REV005B
GB
SYSTEM ERRORS
System errors may arise when the chain counter chain counter is turned on.
Checksum error
The following windows are displayed if the chain counter detects an error in the memorized data:
CONTROL CHECKSUM
TRUE: XXXX
SUM: YYYY
FLASH CHECKSUM
ERROR
CONTROL EEPROM
TRUE: XXXX
SUM: YYYY
EEPROM CHECKSUM
ERROR
MULTI MASTER
SET VALUE:
ERROR
MASTER SLAVE
SPEED 0 M / M
CLOCK BAT LOW
Clock battery low
This fault is displayed if the voltage of the clock battery drops below
2.80Vdc. The chain counter checks the battery voltage when turned on and
every half hour. The problem is reset if the voltage is higher than or equal
to 2.80Vdc. The clock battery can be replaced only at an authorized service
center.
The window shown below appears when this problem is present:
SYSTEM FAULTS
System faults that appear on the state line divided into three categories which are shown below: pro-
blems with automatic reset, problems with automatic reset and keys locked and problems with manual
reset.
PROBLEMS WITH AUTOMATIC RESET
These faults are automatically reset as soon as the cause that had generated the problem disappears.
Select chain counter's priority in the CAN network
(see chapter MULTIPLE CHAIN COUNTERS).
EEPROM memory checksum errorFLASH memory checksum error
If one of these messages appears do not use the chain counter and contact a service center or QUICK
®
customer service without delay.
Multi Master error
If the chain counter detects more then one of MASTER chain counters in
the CAN network, the following window is displayed:
Low voltage
This fault is displayed if the voltage drops below 10.5Vdc for more than
one second. Reset takes place if the voltage is higher than 11.0Vdc for
more than one second. Check the charge level of the batteries that supply
voltage or the electrical system.
The window shown below appears when this problem is present:
SPEED 0 M / M
LOW VOLTAGE
SYSTEM ERRORS AND FAULTS