Page #7 background imageLoading...
Page #7 background image
Air
Blower Performance Data
R96V Series
7
MODEL NUMBER R96VA0402317MSA R96VA0602317MSA R96VA0702317MSA R96VA0852521MSB R96VA1002521MSA R96VA115524MSA
TARGET
GAS
HEATING
AIRFLOW
HIGH
HEATING
CFM [L/s]
SW 15 =
OFF
SW 16 =
OFF
1050 1025 1015 1470 1710 1450
[496] [484] [479] [694] [807] [684]
SW ON =
ON
SW 16 =
OFF
800 880 950 1235 1490 1300
[378] [415] [448] [583] [703] [614]
SW 15 =
OFF
SW 16 =
ON
1200 1250 1190 1850 1965 1700
[566] [590] [562] [873] [927] [802]
SW 15 =
ON
SW 16 =
ON
700 780 900 1120 1400 1225
[330] [368] [425] [529] [661] [578]
LOW
HEATING
CFM [L/s]
SW 13 =
OFF
SW 14 =
OFF
910 925 900 1300 1500 1250
[429] [437] [425] [614] [708] [590]
SW 13 =
ON
SW 14 =
OFF
690 750 770 1065 1335 1060
[326] [354] [363] [503] [630] [500]
SW 13 =
OFF
SW 14 =
ON
1040 1210 1050 1775 1800 1400
[491] [571] [496] [838] [850] [661]
SW 13 =
ON
SW 14 =
ON
607 660 700 925 1210 960
[286] [311] [330] [437] [571] [453]
TARGET
COOLING/
HEAT-PUMP
AIRFLOW
HIGH
COOLING
CFM [L/s]
SW 4 =
OFF
SW 5 =
OFF
1050 1050 1050 1750 1750 1750
[496] [496] [496] [826] [826] [826]
SW 4 =
ON
SW 5 =
OFF
875 875 875 1400 1400 1400
[413] [413] [413] [661] [661] [661]
SW 4 =
OFF
SW 5 =
ON
700 700 700 1225 1225 1225
[330] [330] [330] [578] [578] [578]
SW 4 =
ON
SW 5 =
ON
525 525 525 1050 1050 1050
[248] [248] [248] [496] [496] [496]
LOW
COOLING
CFM [L/s]
SW 4 =
OFF
SW 5 =
OFF
788 788 788 1313 1313 1313
[372] [372] [372] [619] [619] [619]
SW 4 =
ON
SW 5 =
OFF
656 656 656 1050 1050 1050
[310] [310] [310] [496] [496] [496]
SW 4 =
OFF
SW 5 =
ON
525 525 525 919 919 919
[248] [248] [248] [434] [434] [434]
SW 4 =
ON
SW 5 =
ON
394 394 394 788 788 788
[186] [186] [186] [372] [372] [372]
*S = Standard Models
NOTE Standard model complies with California low NOx requirements.
[ ] Designates Metric Conversions.