Engine SP Mode
SM 5-37 D245/D246/D247
Maintenance
5.2.7 SP7-XXX (DATA LOG 1)
7001
[Distance Counter]
Displays the total operation distance.
7-001-001
- *ENG [0 to 4294967295/ 0 / 1 mm / step]
7621 [PM Count:Pages]
Displays the page counter for each PM part.
7-621-002
#PCDU *ENG [0 to 99999999/ 0 / 1 page / step]
7-621-108
Paper Transfer Ro *ENG [0 to 99999999/ 0 / 1 page / step]
7-621-115
Fusing Unit *ENG [0 to 99999999/ 0 / 1 page / step]
7622 [PM Counter Reset]
Clears the page counter for each PM part.
7-622-002
#PCDU ENG [0 to 1/ 0 / 1 / step]
7-622-108
Paper Transfer Ro ENG [0 to 1/ 0 / 1 / step]
7-622-115
Fusing Unit ENG [0 to 1/ 0 / 1 / step]
7623 [PM Set:Life Pages]
7-623-002
Paper Transfer Ro *ENG DFU
7-623-115