8000m Series
- 30 -
Chapter 4 Function Parameter Table
4.1 Symbol Conventions:
“○”: The parameters can be modified both at stop and running status.
“◎”: The parameters cannot be modified at running status.
“●”: The parameters are actual-detecting record value or factory preserved settings
and cannot be modified.
4.2 Function Parameter Table
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F0 Group: Basic Parameters
F0.00
Control mode
selection
0: Reserved
1:V/F control
1 ●
F0.01
Control command
source
0:Keypad
1:Terminals
2: Communications (RS485)
0 ●
F0.02
Options for keypad
/ terminals
frequency
ascending and
descending control
0: Valid and saved when
power-off
1: Valid and not saved when
power-off
2: Invalid
3: Valid at running status.
Changed into the setting value
of F0.08 when restart after stop.
0 ○
F0.03
Settings of master
frequency source X
0: Up/down key
1: Potentiometer of panel
2: AVI terminal
1 ●