EasyManuals Logo

Samsung AM053FXMDCH User Manual

Samsung AM053FXMDCH
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Section 0
Samsung Electronics 1
Contents
. Precautions .............................................................................................................1
1-1 Precautions for the Service...........................................................................................................................................1
1-2 Precautions for the Static Electricity and PL ..........................................................................................................1
1-3 Precautions for the Safety .............................................................................................................................................1
1-4 Precautions for Handling Refrigerant for Air Conditioner ...............................................................................2
1-5 Precautions for Welding the Air Conditioner Pipe .............................................................................................2
1-6 Precautions for Additional Supplement of Air Conditioner Refrigerant ...................................................2
1-7 Other Precautions ............................................................................................................................................................2
. Product Specifications ...........................................................................................3
1. The Feature of Product .....................................................................................................................................................3
1-1 Feature .......................................................................................................................................................................3
2. Product Specifications ......................................................................................................................................................9
. Disassembly and Reassembly ............................................................................ 10
1. Necessary Tools ................................................................................................................................................................. 10
2. Disassembly and Reassembly ..................................................................................................................................... 11
2-1. AM036/048/053FXMDCH ............................................................................................................................... 11
2-2. AM060MXMDCH ................................................................................................................................................ 20
. Troubleshooting ................................................................................................. 30
1. Error Display ....................................................................................................................................................................... 30
2. Error Code............................................................................................................................................................................ 31
3. Appropriate Measures for Different Symptom .................................................................................................... 33
3-1. Error due to repeated address setting (E-108) ....................................................................................... 33
3-2. Communication error between indoor and outdoor unit (E-201) ................................................ 34
3-3. Communication error on all PBA within the outdoor unit C-Box,
communication cable error. (E-205) ............................................................................................................ 36
3-4. Error on outdoor temperature sensor of outdoor unit (Short or open). (E-221) ...................... 37
3-5. Error on COND OUT temperature sensor of main outdoor unit (Short or open). (E-231) .... 38
3-6. Error on discharge temperature sensor of compressor 1 (Short or open). (E-251) ................. 39
3-7. Discharge temperature sensor of compressor 1 is detached from the sensor holder
on the pipe. (E-262) / Top sensor of compressor 1 is detached (E-266) .......................................... 40
3-8. Suction temperature sensor is detached from the sensor holder on the pipe. (E-269) ........ 41
3-9. Refrigerant leakage or error on high pressure sensor (Short or open). (E-291) ........................ 42
3-10. Refrigerant leakage or error on low pressure sensor (Short or open). (E-296) .......................43
3-11. Error on suction temperature sensor (Short or open). (E-308) .....................................................44
3-12. Error on temperature sensor of double layer pipe/
liquid pipe(sub heat exchanger) (Short or open). (E-311) ................................................................ 45
3-13. Error on EVI (ESC) IN temperature sensor (Short or open). (E-321) ............................................. 46
3-14. Error on EVI (ESC) OUT temperature sensor(Short or open). (E-322).......................................... 47
3-15. Error due to operation failure of Fan1 (E-446) ....................................................................................... 48
3-16. Lock error on Fan1 of outdoor unit. (E-448) ........................................................................................... 50
3-17. Error due to overheated motor of outdoor unit's Fan1. (E-453) ..................................................... 51
3-18. Error due to overheated IPM of Fan1. (E-455) ........................................................................................ 52
3-19. Output current sensor error of inverter PBA 1. (E-468) /
Error due to input current of inverter 1. (E-485) / ................................................................................ 53
3-20. DC voltage sensor error of inverter PBA 1. (E-469) ............................................................................ 54
3-21. Compressor operation stop due to high pressure protection control. (E-407) ..................... 55

Table of Contents

Other manuals for Samsung AM053FXMDCH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung AM053FXMDCH and is the answer not in the manual?

Samsung AM053FXMDCH Specifications

General IconGeneral
BrandSamsung
ModelAM053FXMDCH
CategoryAir Conditioner
LanguageEnglish

Related product manuals