Samsung Electronics 41
3-8. Suction temperature sensor is detached from the sensor holder on the pipe. (E-269)
Outdoor unit Display E-269
Indoor unit Display
Duct, Cassette (1 / 2Way), Console, Ceiling
Operation Defrost Timer Fan Filter / MPI
××
◑ ◑
◑
Cassette (4Way / Mini 4Way)
Operation Defrost Timer Filter
×
◑
◑ ◑
Duct, Cassette (1/2 Way), Console, Ceiling
Operation Timer Turbo 24°C 27°C
× ×
◑ ◑
◑
※ ●
: ON
◑
: Flash ×: OFF
Judgement Method
t+VEHNFOU.FUIPE%JGGFSFODFPGTVDUJPOUFNQFSBUVSFPGDPNQSFTTPSTUBSUJOH
verge and suction temperature that is on present operation : If less than 2 °C for
30 minutes to keep.(Judgment at heating operation only)
Cause of problem t4VDUJPOUFNQFSBUVSFTFOTPSCSFBLBXBZEFGFDUJWF
Yes
Is Suction sensor
and sensor Holder accurately
attached?
Is Suction sensor
resistance value reasonable?
(Refer to E231 )
Complete.
Re-insert sensor OR and re-attach sensor holder.
Defective sensor : Replace sensor.
Yes
No
No