6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit KS0971
Outdoor Unit C0971
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor + Compressor
Performance at 115V Single-phase 60Hz
Rating conditions Running amp. A 0.45
Power input W
A
W
45
7.15
710
Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature: 95°F (35°C) D.B.
Cooling
7.6
755
Indoor Unit KS0971
Outdoor Unit CL0971
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor + Compressor
Performance at 115V Single-phase 60Hz
Rating conditions Running amp. 0.45
Power input 45
7.15
710
Cooling
7.6
755
Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature: 95°F (35°C) D.B.
26