7. POWER STAGE
The DC voltages required at various parts of the chassis and panel are provided by a main power supply
unit. MB60 chassis can operate with IPS60, IPS16, IPS17, PW26, PW27 as main power supply and also with
12V adaptor.
CN706 is used for IPS60, IPS16 and IPS17 and CN1 is used for PW26 and PW27.
JK9 is used for the adapter option and also CN705 inverter socket or DB32 chassis with CN706 is used to
supply backlight.
The power supplies generate 18V, 12V, 5V, 3,3V and 12V, 5V, standby mode DC voltages. Power stage
which is on-chassis generates 5V, 3V3 stand by voltage and 12V, 8V, 5V, 3V3, 2.5V, 1,8V and 1,2V supplies
for other different parts of the chassis. Chassis block diagram is indicated below.

Table of Contents