EasyManuals Logo
Home>Sharp>Microwave Oven>R-3A53

Sharp R-3A53 User Manual

Sharp R-3A53
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
R-3A53
R-3A53B
SERVICING
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part
of the high voltage circuit will result in electrocution.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high voltage capacitor.
REMEMBER TO CHECK 4R
1) Reconnect all leads removed from components
during testing.
2) Replace the outer case (cabinet).
3) Reconnect the supply.
WARNING AGAtNST THE CHARGE OF THE
HIGH-VOLTAGE CAPACITOR
4) Run the oven. Check all functions.
The high-voltage capacitor remains charged
about 60 seconds after the oven has been
switched off. Wait for 60 seconds and then
short-circuit the
connection of the
high-voltage capacitor (that is, of the con-
necting lead of the high-voltage rectifier)
against the chassis with the use of an insu-
lated screwdriver.
Sharp recommend
that
wherever
possible
fault-finding is carried out with the supply discon-
nected. It may in, some cases, be necessary to
connect the supply after the outer case has been
removed, in this event carry out $J checks and then
disconnect the leads to the prrmary of the power
transformer. Ensure that these leads remain isolated
from other components and the oven chassis. (Use
insulation tape if necessary.) When the testing is
completed carry out 3D checks and reconnect the
leads to the primary o-he power transformer.
Microwave ovens should not be run empty. To test
for the presence of microwave energy within a
cavity, place a cup of cold water on the oven
turntable, close the door and set the microwave
timer for two (2) minutes. Set the power level to
HIGH and push the START button. When the two
minutes has elapsed (timer at zero) carefully check
that the water is now hot. If the water remains cold
carry out 30 checks and re-examine the con-
nections to the component being tested.
When all service work is completed, and the oven is fully assembled, the microwave power output should
be checked and a microwave leakage test carried out.
TROUBLESHOOTING GUIDE
When troubleshooting the microwave oven, it is
helpfull to follow the Sequence of Operation in per-
forming the checks. Many of the possible causes of
trouble will require that a specific test be performed.
These tests are given a procedure letter which will be
found in the “Test Procedure”section.
IMPORTANT: If the oven becomes inoperative be-
cause of a blown fuse (M6.3A) in the
I-st latch switch - 2nd latch switch -
monitor switch - monitor resisitor cir-
cuit, check the 1 st latch switch, 2nd
latch switch, monitor switch and
monitor resistor before replacing the
fuse (M6.3A).