Commissioning
36 © SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
8.5 Expert mode
Use expert mode to set the following functions:
• Function for multifunction input MF:
External teach (factory setting), laser o, multifunctional input MF deac-
tivated
• Level for multifunction input MF:
High active (factory setting), Low active
• For DT35/DL35 distance sensors:
Output behavior for output 2:
4 … 20 mA (factory setting), 0 … 10 V, switching output Q2
Description ActiveLED LEDslow…fast
Function for multi-
function input
Q1 near • LED slow…fast ashes 1 x:
external teach
• LED slow…fast ashes 2 x:
laser o
• LED slow…fast ashes 3 x:
Multifunctional input MF deactivated
Level for multi-
function input
Q1 far • LED slow…fast ashes 1 x:
low active
• LED slow…fast ashes 2 x: high
active
Output behavior
for output Q2
1)
Q2 near • LED slow…fast ashes 1 x: 4 …
20 mA
• LED slow…fast ashes 2 x: 0 …
10 V
• LED slow…fast ashes 3 x: Switch-
ing output
1) For DT35/DL35 distance sensors only
Table 8: Overview of expert mode
Output: The output Q2 is to be set to 0 … 10 V.
1. From operating mode only: Press select and set pushbuttons simulta-
neously for longer than 10 seconds. The LED Q1 near lights up and the
LED slow … fast ashes cyclically according to the previous setting.
2. Keep pressing the pushbutton until the LED Q2 near lights up.
3. Keep pressing the set pushbutton until the desired option has been
set.
• LED slow…fastashes 1 x: 4 … 20 mA
• LED slow…fastashes 2 x: 0 … 10 V
• LED slow…fastashes 3 x: switching output.
4. In order to leave expert mode, press the select and set pushbuttons
for longer than 10 seconds or wait 5 minutes without pushing the
pushbuttons.