18 © Siemens plc1999 | G85139-H1731-U400-D2
Parameter Function Default
P000 Operating display -
P001 ● Display mode 0
P002 ● Ramp up time (seconds) 10.00
P003 ● Ramp down time (seconds) 25.00
P004 ● Smoothing (seconds) 0.0
P005 ● Digital frequency setpoint (Hz) 50.00
P006 Frequency setpoint source selection 1
P007 Keypad control 0
P009 ● Parameter protection setting 0
P011 Frequency setpoint memory 0
P012 ● Minimum motor frequency (Hz) 0.00
P013 ● Maximum motor frequency (Hz) 50.00
P014 ● Skip frequency 1 (Hz) 0.00
P015 ● Automatic restart after mains failure 0
P016 ● Start on the fly 0
P017 ● Smoothing type 1
P018 ● Automatic restart after fault 0
P019 ● Skip frequency bandwidth (Hz) 2.00
P020 Flying start ramp time (seconds) 25.00
P021 ● Minimum analogue frequency (Hz) 0.00
P022 ● Maximum analogue frequency (Hz) 50.00
P023 ● Analogue input type 2
P024 ● Analogue setpoint addition 0
P027 ● Skip frequency 2 (Hz) 0.00
P028 ● Skip frequency 3 (Hz) 0.00
P029 ● Skip frequency 4 (Hz) 0.00
P031 ● Jog frequency right (Hz) 5.00
P032 ● Jog frequency left (Hz) 5.00
P033 Jog Ramp Up time (V3.00) 10.00
P034 Jog Ramp Down time (V3.00) 10.00
P035 Reverse motor direction 0
P041 ● Fixed frequency 1 (Hz) 5.00
P042 ● Fixed frequency 2 (Hz) 10.00
Parameter Function Default
P043 ● Fixed frequency 3 (Hz) 15.00
P044 ● Fixed frequency 4 (Hz) 20.00
P045 Inversion fixed setpoints for fixed
frequencies 1 – 4
0
P046 ● Fixed frequency 5 (Hz) 25.00
P047 ● Fixed frequency 6 (Hz) 30.00
P048 ● Fixed frequency 7 (Hz) 35.00
P050 Inversion fixed setpoints for fixed
frequencies 5 – 7
0
P051
Selection control function (DIN1 –
terminal 5) fixed frequency 3 or binary
fixed frequency bit 0
1
P052 Selection control function (DIN2 –
terminal 6) fixed frequency 2 or binary
fixed frequency bit 1
2
P053 Selection control function (DIN3 –
terminal 7) fixed frequency 1 or binary
fixed frequency bit 2
10
P056 Digital input debounce time 0
P058 ● RUN command delay (seconds) 0.0
P061 Selection relay output RL1 6
P062 Electro-mechanical brake option
control
0
P063 External brake release delay
(seconds)
1.0
P064 External brake stopping time
(seconds)
1.0
P065 Current threshold for relay (A) 1.0
P071 ● Slip compensation (%) 0
P072 ● Slip limit (%) 500
P073 ● DC injection braking (%) 0
P074 ● I
2
t motor derating 0
PO76 Pulse Frequency 0 or 2
P077 Control mode 0
P078 ● Continuous boost (%) 50
P079 ● Starting boost (%) 0
P081 Nominal frequency for motor (Hz)
✩✩✩
P082 Nominal speed for motor (RPM)
✩✩✩
P083 Nominal current for motor (A)
✩✩✩
P084 Nominal voltage for motor (V)
✩✩✩